Method development and validation for simultaneous estimation of netupitant and palonosetron in bulk and pharmaceutical dosage form by using RP-HPLC
https://doi.org/10.54037/WJPS.2021.91212
Keywords:
Netupitant, Palonosetron, Method development, RP-HPLCAbstract
A simple, Accurate, precise method was developed for the simultaneous estimation of the Netupitant and Palanosetron in Tablet dosage form. Chromatogram was run through Std Discovery C18 250 x 4.6 mm, 5. Mobile phase containing Buffer 0.1% OPA (2.2ph): Acetonitrile taken in the ratio 55:45 was pumped through column at a flow rate of 1 ml/min. Buffer used in this method was 0.1% OPA. Temperature was maintained at 30°C. Optimized wavelength selected was 230 nm. Retention time of Netupitant and Palanosetron were found to be 2.325min and 3.026min. %RSD of the Netupitant and Palanosetron were and found to be 0.9 and 0.6 respectively. %Recovery was obtained as 100.28% and 99.76% for Netupitant and Palanosetron respectively. LOD, LOQ values obtained from regression equations of Netupitant and Palanosetron were 1.01, 3.05 and 0.001, 0.003 respectively. Regression equation of Netupitant is y = 13900x + 26511, and y = 563617x + 1740.8 of Palanosetron. Retention times were decreased and that run time was decreased, so the method developed was simple and economical that can be adopted in regular Quality control test in Industries.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2021 Sridhar Siddiraju, Akshay, M. Sudhakar
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.